Page 229 - PHU_User Manual_EN_Rev A
P. 229
APPENDIX
Output power
measurement accuracy W 150 150 150
[1% of Po_rated]
Output voltage mV 100 100 100
measurement resolution
Output current mA 1 1 1
measurement resolution
Output power
measurement resolution W 1 1 1
Input Characteristics for PHU-B series (for 5kW models)
Model PHU-B models
1-Phase, 200 V models: 180 Vac to 265 Vac
Nominal input rating
(Covers 200/ 208/230/240 Vac)
Input frequency range 47 Hz to 63 Hz
Maximum input current 200Vac A 32 A
Inrush current 200Vac A Less than 50 A
Maximum input power VA 6000
Power factor Rated Power > 0.95
Efficiency *14 200 Vac % 86 to 94
Hold-up time 10 ms or greater
Input Characteristics for PHU-B series (for 10kW models)
Model PHU-B models
1-Phase, 200 V models: 180 Vac to 265 Vac
Nominal input rating
(Covers 200/ 208/230/240 Vac)
Input frequency range 47 Hz to 63 Hz
Maximum input current 200Vac A 64 A
Inrush current 200Vac A Less than 100 A
Maximum input power VA 12000
Power factor Rated Power > 0.95
Efficiency *14 200 Vac % 86 to 94
Hold-up time 10 ms or greater
Input Characteristics for PHU-C series (for 5kW models)
Model PHU-C models
Single Phase *15 , 3-Phase, 200 V models: 180
Nominal input rating
Vac to 265 Vac (Covers 200 Vac / 230 Vac)
Input frequency range 47 Hz to 63 Hz
Maximum input current 200Vac A 32 A (L1, L2)
Inrush current 200Vac A Less than 50 A
Maximum input power VA 6000
Power factor Rated Power > 0.95
229